Neuromandala: a signal becomes artistic material
Neuromandala is ODA.dream’s system for using biosignal parameters to shape image, sound and an artistic environment. A participant observes its response and becomes a co-author of the process.
Electrical activity becomes a drawing
Neuromandala is a circular record of changes in brain rhythms over time. An EEG interface records electrical activity at the scalp, and the system maps signal parameters to moving lines. The resulting image can be watched as it develops or saved as a digital artefact. Different works use it as a projection, light or part of a sound environment. MultiSync supports several EEG streams simultaneously; an individual mandala and a shared group composition are distinct representations.
One technology, different artworks
Neuromandala is both a technology and the umbrella name for a family of ODA.dream works. MindGrid presents neuroportraits and a collective visual field; MindShow develops an audiovisual composition. Neurosynchronization explores shared attention, while stage works bring biosignals into the relationship between performers, audiences and images.
Four rhythms and their power
EEG contains oscillations at different frequencies. The versions shown use four bands: theta, alpha, beta and gamma, ordered from slower to faster. They coexist.
Power is estimated for each band: how strongly it contributes to the recorded signal over a time interval. Rhythm power and oscillation frequency are different quantities: higher power does not mean a faster rhythm. The linear plot below shows how the contribution of each band changes over time.
How to read a Neuromandala
Start with line colour: in the archival examples, theta is magenta, alpha turquoise, beta green and gamma yellow.
Movement around the circle represents time; one revolution covers an interval selected for that version.
Distance from the centre represents rhythm power on the image’s scale. In relative mode, this is a share of the displayed bands: an increasing share can reduce the others even when their absolute power has not fallen.
The contour reveals rises, falls and repetitions. Line width, brightness and trails add visual dynamics but are not emotion scales. Drawings and different versions may use different palettes: follow the rhythm labels and scale.
Different drawings in one visual language
Three frames from the MindDB archive show different line relationships and contours. Compare which line sits farther from the centre, where lines converge and how the shape changes around the circle. These are visual examples, not a better–worse scale or a comparison of people: comparing measurements requires matching conditions and settings. The frames are presented without personal identifiers, raw EEG recordings or interpretations of participants’ states.
Observing the response
The participant observes how the drawing changes alongside their experience: attention, breathing, movement or closing their eyes. A line changing alongside a sensation invites observation; it does not establish a cause. Sensor contact, eye movements and muscles affect the signal. A single spike or colour therefore cannot be read as a particular thought, emotion or diagnosis. In the artwork, the dialogue with a responsive environment matters; participation without a sensor and the audience role depend on the format.
EEG interfaces we use
The studio uses the first-generation Muse Headband, Muse 2, Muse S, NeuroPlay and Neiry Pro across its artworks and practices. The interface records a signal; Neuromandala defines the artistic composition and how it develops. Device choice depends on the artwork, venue conditions and participation format. The photographs show EEG interfaces in the context of presentations and encounters.
Technology and invention application
Invention application No. 2026113457/14(030103) was filed on 30 April 2026. A FIPS notice dated 15 June 2026 confirms substantive examination; no patent has been granted. This page uses selected illustrations from the application materials to explain how to read the image.
From measurement to response
Signal
A sensor records limited physiological parameters. EEG configurations use electrical brain activity as their source material.
Artistic rule
Selected parameters are mapped to image or sound characteristics. The rule is defined by the artwork, not by a universal interpretation of a person’s state.
Responsive environment
The generative system changes the composition over time in response to changes in the incoming signal.
Feedback
The participant sees or hears changes, explores them and contributes to how the situation develops.
Person, group, audience
Individual participation
In MindShow, one person enters an observation session and may add a personal narrative, depending on the version. The result can become a digital artefact.
Shared field
In Neurosynchronization and stage works, interaction among several people becomes part of a shared visual process. The number of measured participants differs from the audience size.
Observation and dialogue
An audience member can observe the process, discuss what they see and join a public conversation. Being present does not itself mean having biosignals measured.
Limits of interpretation
- Measurement does not explain a person’s thoughts, emotions, personality or health.
- A shared image does not prove psychological or physiological “synchrony” in a group.
- Consent, recording, data retention and artefact delivery are specified for each presentation.